====== Piktul Setup ====== | ====== Piktul Setup ====== | ||
- | This page describes how to get it connected up and ready for use through Matlab. | + | This page describes how to get it connected up and ready for use through Matlab. |
+ | |||
+ | Since we are sharing the lab, I am afraid that you will have to setup and cleanup the manipulator each time. Here is how the setup goes: | ||
+ | |||
+ | 1. First, you'll have to move the other lab's stuff by sort of piling it up in the corner. | ||
+ | ;#; | ||
+ | {{ECE4560: | ||
+ | ;#; | ||
+ | |||
+ | 2. Second, grab a manipulator from the shelf and bring it to desk. If the manipulator has the controller board and an AC/DC adaptor with it, then it is functional. | ||
+ | ;#; | ||
+ | {{ECE4560: | ||
+ | ;#; | ||
+ | |||
+ | 3. You have to reach behind the monitor and grab the serial cable. | ||
+ | ;#; | ||
+ | {{ECE4560: | ||
+ | ;#; | ||
+ | |||
+ | 4. Connect the serial cable up. Also connect the AC/DC into a power source and to the manipulator' | ||
+ | ;#; | ||
+ | {{ECE4560: | ||
+ | ;#; | ||
+ | |||
+ | 4. It helps to also grab the cardboard cut-out for the manipulator since it has a workspace grid on it. There are a bunch of them to the left of the shelf on the floor (in between the two shelves there in the room). I think I miss-printed the reachable workspace on the grid, so it might be off. I'll probably try to reprint this semester when I get around to it. | ||
+ | ;#; | ||
+ | {{ECE4560: | ||
+ | ;#; | ||
+ | |||
+ | 5. You will have to pick a sleep position. | ||
+ | |||
+ | 5. When you are done, please make sure to put back how you found it. Especially the controller board and the adaptor, as that is how we know the manipulator is functional. | ||
+ | |||
+ | ----- | ||
+ | |||
+ | Once you get good at it, this part shouldn' | ||
+ | |||
+ | You can re-run the calibration with you parameters much like with the '' | ||
+ | < | ||
+ | piktul_calibrate(load(' | ||
+ | </ | ||
+ | The calibration will start with your saved values. | ||
+ | |||
+ | --------- | ||
+ | ;#; | ||
+ | [[ece4560: | ||
+ | ;#; |
ece4560/piktul/setup.1425322584.txt.gz · Last modified: 2024/08/20 21:38 (external edit)